Search results for " Experimental surgery"

showing 5 items of 5 documents

Electrospun PHEA-PLA/PCL Scaffold for Vascular Regeneration: A Preliminary in Vivo Evaluation

2017

Abstract Background There is increasing interest in the development of vessel substitutes, and many studies are currently focusing on the development of biodegradable scaffolds capable of fostering vascular regeneration. We tested a new biocompatible and biodegradable material with mechanical properties similar to those of blood vessels. Methods The material used comprises a mixture of α,β-poly(N-2-hydroxyethyl)- d,l -aspartamide (PHEA) and polylactic acid (PLA), combined with polycaprolactone (PCL) by means of electrospinning technique. Low-molecular-weight heparin was also linked to the copolymer. A tubular PHEA-PLA/PCL sample was used to create an arteriovenous fistula in a pig model wit…

ScaffoldMaterials scienceBiocompatibilityPolymersSwinePolyesters0206 medical engineering02 engineering and technologySettore MED/22 - Chirurgia VascolareNeovascularizationchemistry.chemical_compoundPolylactic acidBlood vessel prosthesismedicineAnimalsTransplantationRegeneration (biology)Bioabsorbable scaffold Bioengineered vascular scaffold Experimental surgery021001 nanoscience & nanotechnology020601 biomedical engineeringBlood Vessel ProsthesisSettore MED/18 - Chirurgia GeneraleCoagulative necrosischemistrySettore CHIM/09 - Farmaceutico Tecnologico ApplicativoPolycaprolactoneSurgerymedicine.symptomPeptides0210 nano-technologyBiomedical engineeringTransplantation Proceedings
researchProduct

Electrospun Polyhydroxyethyl-Aspartamide-Polylactic Acid Scaffold for Biliary Duct Repair: A Preliminary In Vivo Evaluation

2017

Abstract Tissue engineering has emerged as a new approach with the potential to overcome the limitations of traditional therapies. The objective of this study was to test whether our polymeric scaffold is able to resist the corrosive action of bile and to support a cell's infiltration and neoangiogenesis with the aim of using it as a biodegradable tissue substitute for serious bile duct injuries. In particular, a resorbable electrospun polyhydroxyethyl-aspartamide–polylactic acid (90 mol% PHEA, 10 mol% PLA)/polycaprolactone (50:50 w/w) plate scaffold was implanted into rabbit gallbladder to assess the in vivo effects of the lytic action of the bile on the scaffold structure and then as a tu…

ScaffoldMaterials sciencePolyesters03 medical and health scienceschemistry.chemical_compound0302 clinical medicineBioabsorbable scaffold Bioengineered biliary duct Experimental surgeryTissue engineeringPolylactic acidIn vivomedicineAnimalsTransplantationTissue EngineeringTissue ScaffoldsBile ductGallbladderBiliary Tract Surgical ProceduresSettore MED/18 - Chirurgia Generalemedicine.anatomical_structurechemistryBiliary tractSettore CHIM/09 - Farmaceutico Tecnologico Applicativo030220 oncology & carcinogenesisPolycaprolactone030211 gastroenterology & hepatologySurgeryBile DuctsRabbitsBiomedical engineering
researchProduct

Obtaining mesenchymal stem cells from adipose tissue of murine origin: Experimental study

2015

Stem cells have a key role in regenerative medicine and tissue engineering. Although not immortal, they are able to expand manyfold in culture retaining at the same time their growth and multilineage potential. They also show a migratory capacity when transplanted systemically in animal model with injuries. Thanks to their properties and their plasticity stem cells are of great importance since they can be used as a tool for repair damaged tissues and organs. Mesenchymal stem cells, in particular, have the ability to differentiate into lineages of mesodermal tissues, such as skeletal muscle, bone, tendons, cartilage, and fat under appropriate culturing conditions. Recent evidence suggest th…

Settore MED/18 - Chirurgia GeneraleStem cellSettore BIO/13 - Biologia ApplicataBiotechnology; Experimental surgery; Stem cells; Regenerative medicineRegenerative medicineExperimental surgerySettore VET/08 - Clinica Medica VeterinariaBiotechnology
researchProduct

Simple and fast orotracheal intubation procedure in rat

2016

Introduction: Endotracheal intubation in the rat is difficult because of extremely small size of anatomical structures (oral cavity, epiglottis and vocal cords), small inlet for an endotracheal tube and the lack of proper techniacal instruments. Matherial and Methods: In this study we used seventy rats weighthing 400-500 g. The equipment needed for intubation was an operating table, a longish of cotton, a cotton tip, orotracheal tube, neonatal laryngoscope KTR4, small animal ventilator, and isoflurane for inhalation anaesthesia. Premedication was carried out by medetomidine hydrochloride 1 mg/mL; then, thanks to a closed glass chamber, a mixture of oxygen and isoflurane was administered. By…

Settore MED/18 - Chirurgia Generaleendotracheal intubation in rat simple and fast orotracheal intubation inhalation anaestesia experimental surgerySettore MED/41 - AnestesiologiaSettore BIO/06 - Anatomia Comparata E Citologia
researchProduct

A tissue-engineered artificial bile duct grown to resemble the native bile duct in a porcine model

Settore MED/18 - Chirurgia Generalescaffold tissue engineering bile-duct experimental surgery pig
researchProduct